Search
Now showing items 1-2 of 2
Implimenting the NZSEE Seismic Isolation Guidlines: a practioners view over three new designs
(New Zealand Society for Earthquake Engineering, 2020-04-22)
The draft seismic isolation guidelines provide a significant step forward in promoting a consistent NZ approach to designing and demonstrating compliance in isolated buildings. This paper provides a practitioners’ point ...
Scion Hub: A three storey seismically resilient timber diagrid
(New Zealand Society for Earthquake Engineering, 2020-04-22)
The new three storey Hub building at Scion’s campus in Rotorua is an innovative approach to providing seismic resilience in timber. A demonstration project for Scion’s work in the timber industry it utilises several forms ...