    The sliding hinge joint moment connection

    Thumbnail
    Date
    2010-09-30
    Authors
    MacRae, Gregory A.
    Clifton, G. Charles
    Mackinven, Hamish
    Mago, Nandor
    Butterworth, John
    Pampanin, Stefano
    Metadata
    Show full item record
    Abstract
    A new friction moment joint for steel framed structures is described. It has a similar cost to conventional construction and is designed such that there is negligible damage to the frame or slabs. Experimental testing shows that steel, brass or aluminium shims can provide satisfactory friction resistance and that there is almost no damage to the frame during design level displacements. A method for establishing the dependable friction force is developed considering construction tolerances and bolt moment-axial-force-shear interaction. A design methodology for the joint and a design example are provided.