    The serviceability of normal-use, non-domestic buildings in earthquakes

    Thumbnail
    Date
    2006-12-31
    Author
    Dowrick, David
    Metadata
    Show full item record
    Abstract
    This paper reports on an empirical study of whether it is necessary to carry out design checks on the serviceability of normal-use non-domestic buildings in earthquakes in New Zealand. It is found that at the relevant hazard level, i.e. at a return period of 25 years, the highest intensity anywhere in New Zealand is Modified Mercalli VII (MM7). At that intensity, no loss of function (predictable by a serviceability design check) has been reported in any structures classified as Buildings Type III (brittle) or better, since the introduction of reinforced concrete construction. For normal-use non-domestic structures designed for the ultimate limit state earthquake loading, the author contends (with one interim proviso affecting 10 percent of the country) that serviceability can be deemed to be satisfactory for new buildings anywhere in the New Zealand.
    URI
    https://doi.org/10.5459/bnzsee.39.4.208-214
    Published in
    • Bulletin of the New Zealand Society for Earthquake Engineering

    Contact Us | Send Feedback
     

     

    Browse

    Entire RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Contact Us | Send Feedback