Hysteretic restoring force characteristics of unbounded prestressed concrete framed structure under earthquake load
Abstract
An analytical method, by which hysteretic restoring force characteristics of unbonded prestressed concrete framed structure can be statically pursued on the basis of material properties, is presented. The bond-slip relationship between concrete and prestressing tendon is taken into account, and thus the method covers unbonded members and bonded members. For verifying the propriety of the analytical method, the experiment is carried out on a portal frame with an unbonded prestressed concrete beam of 4.2 m in length and reinforced concrete columns of 1 m in height. High intensity reversed cyclic lateral loading is applied. The experimental results show a good agreement with the analytical ones in terms of load-deflection relation and the fluctuation of the tendon stress at anchorage end.