Show simple item record

dc.creatorTyler, R. G.
dc.creatorHeine, A. J.
dc.date1984-03-31
dc.identifierhttps://bulletin.nzsee.org.nz/index.php/bnzsee/article/view/903
dc.identifier10.5459/bnzsee.17.1.47-55
dc.descriptionTests on a steel energy absorber loaded axially in push-pull are described. The device is intended for use in diagonal bracings or in other convenient positions in building frameworks. It was concluded that the device tested would perform adequately as an energy absorber at a stroke of ±6 mm when the strain would be about ±3% and the life about 80 cycles. Care is needed in restraining such a device against buckling in the compression part of the cycle and full-scale testing is required to establish performance characteristics in an actual structure.en-US
dc.formatapplication/pdf
dc.languageeng
dc.publisherNew Zealand Society for Earthquake Engineeringen-US
dc.relationhttps://bulletin.nzsee.org.nz/index.php/bnzsee/article/view/903/878
dc.sourceBulletin of the New Zealand Society for Earthquake Engineering; Vol 17 No 1 (1984); 47-55en-US
dc.source2324-1543
dc.source1174-9857
dc.titleTests on an axially loaded steel energy absorberen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeArticleen-US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record