Search
Now showing items 1-2 of 2
Seismic retrofit of historic timber structures: Uncertainties and adaption on site
(New Zealand Society for Earthquake Engineering, 2022-04-27)
Existing timber structures, containing more hand-adapted and degradable components than other materials, provide challenges in ensuring your design intent is followed through on site. Often these buildings are flexible ...
Seismic strengthening of the Seatoun Tunnel
(New Zealand Society for Earthquake Engineering, 2022-04-27)
The Seatoun tunnel is a 147m long, vehicle and pedestrian tunnel built in 1906-1907 to provide a tram connection between the suburb of Seatoun the city of Wellington. In 2011, the Seatoun tunnel structure was assessed as ...