    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Shaking table tests of a base isolated structure with Double Concave Friction Pendulum bearings

    Thumbnail
    Date
    2015-06-30
    Authors
    Ponzo, Felice C.
    Cesare, Antonio D.
    Leccese, Gianmarco
    Nigro, Domenico
    Metadata
    Show full item record
    Abstract
    An extensive experimental testing programme named JETBIS project (Joint Experimental Testing of Base Isolation Systems) was developed within the RELUIS II project (Task 2.3.2) and RELUIS III project (Line 6) involving partners from different Italian universities. This paper describes the seismic tests performed by the research unit of University of Basilicata (UNIBAS) on an isolation system based on Double Concave Friction Pendulum (DCFP) bearings. The DCFP bearing contains two separate concave sliding surfaces and exhibits different hysteretic properties at different stages of displacement response. The main objective of this work is to evaluate the horizontal response of the DCFP isolators by means of controlled-displacement tests and shaking table tests. The experimental model was a 1/3 scaled steel framed structure with one storey and one bay in both directions. Four DCFP bearings with equal properties of the sliding surfaces were considered. In this work, three different sliding surface conditions (with and without lubrication) have been studied. The isolated base model was subjected to 8 natural earthquakes of increasing seismic intensities and considering two mass configurations (with both symmetrical and eccentric masses). The reliability of the design procedure considered for the isolation system was verified also when relevant residual displacements occurred due to previous earthquakes. In this paper, the comparisons between the experimental outcomes and the numerical results of nonlinear time-history analyses using SAP2000 are shown.
    URI
    https://doi.org/10.5459/bnzsee.48.2.136-144
    Published in
    • Bulletin of the New Zealand Society for Earthquake Engineering