    Wellington Central Police Station base isolation maintenance

    Thumbnail
    Date
    2013-09-30
    Author
    Smart, C. R.
    Metadata
    Show full item record
    Abstract
    Wellington Central Police Station was built in the late 1980s. Its 10-storey tower block featured robust X-bracing around the perimeter and strong floor diaphragms to distribute earthquake actions amongst the perimeter frames, thus making it extremely stiff. To provide the ductility required by the 1984 Loadings Standard, the tower block was supported on a base isolation system that allowed up to 400 millimetres of movement in any horizontal direction. This paper describes investigations into the continuing serviceability of the base isolation parts, and the remedial maintenance required.
    URI
    https://doi.org/10.5459/bnzsee.46.3.141-156
    Published in
    • Bulletin of the New Zealand Society for Earthquake Engineering