• Login
    View Item 
    •   NZSEE Document Repository
    • New Zealand Society for Earthquake Engineering
    • Proceedings of the 2022 New Zealand Society for Earthquake Engineering Annual Technical Conference
    • View Item
    •   NZSEE Document Repository
    • New Zealand Society for Earthquake Engineering
    • Proceedings of the 2022 New Zealand Society for Earthquake Engineering Annual Technical Conference
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Sustainability in enhancing the resilience of major route in Wellington

    Thumbnail
    Download
    PDF (705.9Kb)
    Date
    2022-04-27
    Authors
    Arumugam, Sivasith
    Brabhaharan, Pathmanathan
    Metadata
    Show full item record
    Abstract
    Uncertainty in the seismicity of Wellington and climate change were key issues that influenced the design of strengthening of a key arterial route in Wellington. The abstract describes the innovations and technology adopted in the project to strengthen a large retaining wall along the Chaytor Street in Wellington, considering sustainability. Strengthening design was developed for two retaining walls along a continuous 220 m long alignment, along the critical Chaytor Street in Wellington to enhance route resilience. MASW geophysical surveying supplemented with few boreholes were carried out as part of site investigations, reducing traffic disruption and materials costs. Preliminary design option comprised more conventional anchors closely spaced along a surface area of nearly 1000 m2. A sustainability assessment was carried out to select the best sustainable option from many other options to strengthen the walls. The relative importance of the three sustainability pillars (environmental, economic, and societal/functional) were key drivers in selecting the option for strengthening the wall. The strengthening scheme comprising a concrete overlay supported by rock anchors and piles, developed using various models for optimized use of materials like steel and concrete. This option made use of the existing unreinforced and lightly reinforced walls with a new structural overlay, connected at the anchor locations to minimize concrete use. Post-grouted rock anchors were adopted to enhance capacity and reduce construction time and environments issues. The integrated three dimensional model was used to consult with stakeholders, and this digital twin will facilitate meaningful construction input and future asset management.
    URI
    https://repo.nzsee.org.nz/handle/nzsee/2500
    Published in
    • Proceedings of the 2022 New Zealand Society for Earthquake Engineering Annual Technical Conference

    Contact Us | Send Feedback
     

     

    Browse

    Entire RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Contact Us | Send Feedback