    Chevron Buckling Restrained Brace Frame Seismic Behaviour Considering Out-of-Plane Effects

    Thumbnail
    Download
    PDF (542.9Kb)
    Date
    2023-04-19
    Authors
    Simpson, Toby
    Donald, Andre
    MacRae, Gregory
    Metadata
    Show full item record
    Abstract
    This project evaluates the behaviour of buckling restrained braces (BRBs) in a chevron configuration considering IP and OOP frame deformations using software capable of second-order inelastic frame analysis. Initially a single-storey, single-bay chevron BRB system, representing a realistic building, was analysed. Performance was assessed to prevent buckling, as well as yielding in elements other than the encased steel core, with IP frame moment demands. Performance assessments then considered the following modifications: (a) changing to a ‘super-X’ configuration (b) increasing the gusset plate (GP) stiffnesses, (c) changing the beam stiffness, and (d) shortening the casing length to account for flexibility at the casing ends. For the initial chevron configuration, the ratio of the maximum brace force obtained according to the AISC provisions, Cmax, to the system Euler buckling axial force, Pe, was 0.389. This exceeded the maximum allowable Cmax/Pe of 0.285. The observed difference for the super-X was insignificant. Increasing the GP stiffness decreased Cmax/Pe to as low as 0.215. Once cover plates were added, increasing the beam stiffness was insignificant for buckling. A lateral restraint OOP at the beam-brace joint had an insignificant effect on Pe unless no cover plates are provided, in which case Pe increased by 6.8%. Considering the initial chevron configuration with the casing length reduced at each end by the casing width, Cmax/Pe increased to 0.426. In critical yielding elements it was found that IP frame deformations could contribute as much as 25% to the total gusset plate yield, and therefore should not be ignored.
    URI
    https://repo.nzsee.org.nz/handle/nzsee/2610
    Published in
    • Proceedings of the 2023 New Zealand Society for Earthquake Engineering Annual Technical Conference

    Contact Us | Send Feedback
     

     

    Browse

    Entire RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Contact Us | Send Feedback